The Controls Your Facilities Team Needed, Automated.
From zone HVAC setpoints to anomaly detection, DomeSystems identifies manual building decisions and manages them continuously.
Every zone live, with setpoints managed automatically.
View each zone's temperature, setpoint, and HVAC status live. When a zone leaves its model-predicted range, DomeSystems sends a setpoint command.
| Zone | Current Temp | Setpoint | Mode | Status | Override |
|---|---|---|---|---|---|
| Zone 1 - Office East | 72.4 F | 71.0 F | Cooling | Active | None |
| Zone 2 - Conference A | 74.1 F | 70.0 F | Cooling | Active | None |
| Zone 3 - Server Room | 68.0 F | 68.0 F | Cooling | Active | None |
| Zone 4 - Lobby North | 70.8 F | 72.0 F | Off | Idle | None |
| Zone 5 - Floor 4 Open | 73.5 F | 75.0 F | Heating | Override | Facilities request |
| Zone 6 - Parking Deck | 61.2 F | 62.0 F | Off | Idle | None |
Schedules adapt to your buildings, not vice versa
DomeSystems uses occupancy sensors and calendar signals to create zone schedules. Monday morning is unlike Friday afternoon, and holiday weeks differ from conference weeks. No manual update is needed.
- Uses 30 days of sensor history before recommending schedules
- Accounts for calendar exceptions: public holidays, building closures, one-off events
- Floor and zone level detail, rather than one building-wide block
- Facilities staff may review and approve schedules before activation
Energy use by zone, floor, and building
DomeSystems records energy use at the detail facilities teams need for lease accounting, ESG reporting, and tenant billing. Roll up or drill down without a facilities audit.
- Zone kWh tracking, plus before-and-after comparison per schedule change
- Weekly emails for facility managers and operations leads
- CSV exports for energy management system integration
- Metrics available through an API for custom dashboards and reporting
Warnings before issues become complaints
DomeSystems identifies zones departing from expected energy profiles. Equipment problems typically appear in data days before a fault code or tenant call.
Unusual Energy Use
Alerts when a zone uses far more energy than its model predicts from occupancy and weather. Causes include stuck dampers, failing valves, and unauthorized space heaters left on.
Equipment Fault Patterns
Finds clusters linked to common HVAC faults, including chiller cycling anomalies, compressor short-cycling, and air handler static pressure drift. Flags them before the equipment logs a fault code.
Schedule Mismatch
Notifies you when activity differs from the learned schedule beyond a configurable threshold. Helps detect unauthorized after-hours access or unexpected occupancy in leased spaces.
First building connected in under a week
DomeSystems connects read-only to your BMS and begins zone models immediately. No hardware to install.